1.2 Failure Time Analysis
In this topic we present a set of statistical techniques for analyzing durability data from a homogeneous population. Heterogeneous populations occur in the context of accelerated life tests, which will be addressed via regression models. Time to failure analysis answers questions related to the lifetime of products and components. To introduce the basic concepts, we will present an example.
Example 2.1
A fan drive valve is evaluated for its lifetime. The manufacturer subjects several valves to tests where their operation is accelerated to obtain information about the reliability of the product.
A common type of test is one in which the valve is placed in a tank of water, which is heated and cooled, accelerating the valve’s operation. It is estimated that 30,000 cycles (one cycle corresponds to the act of opening and closing the valve) are equivalent to 10 years of use under normal conditions. Consider the situation in which a batch of 30 new mechanisms was put to test. The test consists of leaving them in operation for a period of up to 50,000 cycles and recording, for each mechanism, the number of cycles it completed until it failed. After the test, 18 mechanisms had failed before completing 50,000 cycles and the rest continued to work.
The number of cycles to failure for these 18 mechanisms were:
| 5.626 | 11.223 | 12.128 | 13.566 | 14.922 | 16.513 | 22.138 | 26.791 | 27.144 |
| 27.847 | 28.613 | 31.225 | 36.229 | 38.590 | 39.580 | 40.278 | 41.325 | 44.540 |
| 50.000+ | 50.000+ | 50.000+ | 50.000+ | 50.000+ | 50.000+ | 50.000+ | 50.000+ | 50.000+ |
Table 1.2.1: Number of cycles
Using this data, the manufacturer would like to answer the following questions:
What is the average number of cycles completed before failure of this mechanism?
Manufacturers provide a two-year warranty on their product and know that the average number of operating cycles of the product over a 2-year period is 6,000 cycles. What is the expected fraction of defects in the first two years?
What is the number of cycles in which 10% of the products will be out of operation?
With this, we introduce the following basic concepts:
1.2.1 Types of Failure
The situations studied in reliability involve the time until the occurrence of an event of interest. These events are, in most cases, undesirable and usually called failures. The first step in studying reliability is to clearly and precisely define what constitutes failure. A reasonable way to define failure is through the consumer’s perspective. The product fails when the consumer says it failed.
For example, in modern coffee makers, water is heated by passing through a hot pipe. Over time, the mineral components in the water accumulate in the pipe, reducing its diameter. The effect of this is to increase the time needed for the coffee to be ready. One way to define failure from the consumer’s perspective would then be to define it in terms of the coffee preparation time. For example, the failure occurs when the time to prepare 8 cups exceeds 10 minutes. An element related to failure time is the measurement scale, in the example discussed the unit of measurement is the number of cycles. Other times we use time.
1.2.2 Censored Data
Tests carried out to obtain product durability measurements are time-consuming and expensive, so tests are usually completed before all items fail. A characteristic resulting from this type of sampling is the presence of censorship or incomplete information. In Example 2.1 presented above we saw that 12 of the 30 mechanisms did not fail until 50,000 cycles. These 12 observations are said to be censored, as they only provide partial information, that is, only that the lifetime of the mechanism is greater than 50,000 cycles. We emphasize that, although partial, these observations provide relevant information about lifespan and should not be disregarded in statistical analysis.
In practice we have some types of censorship, including:
Right-censored: an observation is said to be right-censored at a time L if it is only known that its exact failure time is greater than or equal to L, as in Example 2.1 of valves.
Left censored: analogously, an observation is said to be left censored at a time L if it is only known that its exact failure time is less than or equal to L.
In addition to these two types of censorship, we must choose, when planning the experiment (test), between two censorship schemes: Type I Censorship or Type II Censorship.
Type I Censorship: consists of pre-establishing a period of time for each of the items under study, so that the lifetime of an item is only known if it is shorter than this period. An example of this censoring scheme is given by Example 2.1 in which all items are observed up to a maximum of 50,000 cycles. Note that for this censoring scheme the time each item is under observation is fixed, while the number of units that fail (uncensored observations) is random. This censoring scheme is used when it is possible to plan the duration of the study.
Type II censoring: is one in which only the r smallest observations of a sample of size n are complete, that is, not censored. In other words, we say that the test ends after a pre-established number of items under test have failed. This censorship scheme is used when there is little or no information about the durability of the product.
Furthermore, we have a third censorship scheme, random. This happens in practice, when an item is removed during the test without having reached failure, and may occur if the item fails for a reason other than that studied.
1.2.3 Specifying the Failure Time
The random variable T, which represents the failure time, is usually specified in reliability by its reliability function or by its failure rate function.
1.2.3.1 Reliability Function
This is one of the main probabilistic functions used to describe studies arising from durability tests. The reliability function is defined as the probability of a product performing its function without failing until a certain time t. In probabilistic terms, this is written in terms of the variable of interest T, which is the time until failure occurs, as being
$$R(t) = P[T \geq t]$$
Having the reliability function in hand, we can return to Example 2.1 and answer questions 2 and 3, where the fraction of defects in the first two years of life is around 1% and 10% of products will be out of operation after 10 years of use.
1.2.3.2 Failure Rate Function
The probability of a product failing within a given time interval $[t_{1}$, $t_{2})$ can be expressed in terms of the reliability function as
$$P[t_1 \leq T~<~t_2] = P(T~<~t_2) - P(T~<~t_1)$$
$$= 1 - P(T \geq t_2) - [1 - P(T \geq t_1)]$$
$$= P(T \geq t_1) - P(T \geq t_2)$$
$$= R(t_1) - R(t_2)$$
The failure rate in the interval $[t_{1}$, $t_{2})$ is defined as the probability that the failure will occur within this interval, given that the failure did not occur before $t_{1}$, divided by the length of the interval. Thus, the failure rate in the interval $[t_{1}$, $t_{2})$ is expressed by
$$\dfrac{P(t_1~\leq~T~<~t_2|T~>~t_1)}{(t_2-t_1)}=\dfrac{P(t_1~\leq~T~<~t_2)}{(t_2-t_1)P(T~>~t_1)}= \dfrac{R(t_1)-R(t_2)}{(t_2-t_1)R(t_1)} \tag{2.1}$$
Considering the range $[t, t+Δt)$, $Δt > 0$, expression (2.1) can be rewritten as
$$\dfrac{R(t)-R(t+ \Delta t)}{\Delta t R(t)} \tag{2.2}$$
The instantaneous failure rate at time t will be defined as
$$h(t)=\lim_{\Delta t\to 0^+} \dfrac{P(t \leq T~<~t + \Delta t \mid T~>~t)}{\Delta t}$$
and its expression will be obtained when we make Δt tend to zero in expression (2.2), that is,
$$h(t) = \lim_{\Delta t \to 0^+}\dfrac{R(t)-R(t+ \Delta t)}{\Delta t R(t)}$$
Knowing that R(t) = 1 - F(t) and that the probability density function f(t) is equal to the derivative of the cumulative distribution function F(t), that is,
$$f(t) = \lim_{\Delta t \to 0^+} \dfrac{F(t + \Delta t) - F(t)}{\Delta t}$$
we conclude that the instantaneous failure rate h(t) can be expressed as
$$h(t) = \lim_{\Delta t \to 0^+}\dfrac{R(t)-R(t + \Delta t)}{\Delta t R(t)}$$
$$= \lim_{\Delta t \to 0^+}\dfrac{1 - F(t) - (1 - F(t + \Delta t))}{\Delta t R(t)}$$
$$= \lim_{\Delta t \to 0^+}\dfrac{F(t + \Delta t) - F(t)}{\Delta t R(t)}$$
$$= \dfrac{1}{R(t)}~\lim_{\Delta t \to 0^+}\dfrac{F(t + \Delta t) - F(t)}{\Delta t}$$
$$= \dfrac{f(t)}{R(t)}$$
Note that failure rates are positive numbers but have no upper limit. The failure rate function h(t) is very useful for describing the distribution of product lifetimes. It describes the way in which the instantaneous failure rate changes over time. Figure 1.2.1 shows four failure rate functions, namely:
Increasing: Failure rate increases over time. This is the expected behavior for products or components, showing a gradual aging effect.
Decreasing: The failure rate decreases over time. It is the behavior of certain types of capacitors and some semiconductor devices.
Constant: the failure rate is constant for any value of time. It usually characterizes a period in the lifespan of various manufactured products.
Bathtub: is a combination of the three previous functions, with an initial decreasing period, an approximately constant intermediate period, and an increasing final period. It is believed that the bathtub-type failure rate function describes well the life time behavior of some products that are subject, in an initial period, to a high failure rate (period of premature failures) that decreases rapidly, becoming constant in an intermediate period (useful life period) and presenting an increasing failure rate in the final period (wear period).
Figure 1.2.1: Failure rate functions.
Another widely used relationship between h(t) and R(t) is given by
$$H(t) = \int_0^t h(u)du = \int_0^t \dfrac{f(s)ds}{R(s)} = \int_0^t\dfrac{-d[1-F(s)]}{R(s)} = \int_0^t \dfrac{-d(R(s))}{R(s)}$$
where H(t) is the accumulated failure rate function, used by some authors in graphical analyzes to verify the adequacy of statistical models.