Manufacturers currently face the challenge of developing new products, with more advanced technology and in record time while, at the same time, they must continue efforts to improve productivity, field reliability and quality in general. In practical terms, this means that information regarding product reliability needs to be obtained in a short period of time, so that it can be used in new projects and improving existing ones. Information regarding product performance basically originates from two sources: field data and experimental data (tests).

Field data, as the name suggests, are those arising from a field operation. For some types of product, it is common to carry out a type of “market test” well before its launch. In these cases, a certain number of products are allocated to a sample of consumers, where the product’s performance is observed for a certain period of time under real conditions of use. Another type of field data is obtained through calls to authorized technical assistance services. However, many modern products are designed to operate without failure for years. Therefore, it is expected that few units will fail during the observation period. In particular, data obtained through authorized services is often not completely reliable and is generally only available for products within the warranty period. Once this period ends, monitoring of the product’s “life” is lost. The loss of follow-up is due to two factors: the consumer, for reasons of cost, decides to resort to unauthorized services or the authorized service, even when requested, does not send the necessary information to the manufacturer. In the case of products outside the warranty period, the customer bears the cost of the service. Consequently, from the service provider’s point of view, there is no reason to notify the manufacturer. Due to all the problems exposed, these data sources are often insufficient, making it necessary to collect experimental data. However, tests performed under normal use conditions are time-consuming and expensive. A frequently used way to obtain information more quickly, facilitating the prediction of reliability, is to carry out accelerated tests. In general, the information obtained under high levels of stress, for example rate of use, temperature, voltage, is extrapolated through a statistical-physical model to obtain estimates, for example, of the average or median lifespan under conditions of use. Although accelerated testing is used in one form or another by industries, there are differing opinions regarding how to perform such testing and interpret the data collected. Some questions that commonly arise are:

How many and which stress variables should be used?

How many stress levels should be used? (Is it common to subject all items under test to the same stress level?)

What stress levels should be chosen?

How should stress be applied?

The truth is that accelerated testing, when well understood, carefully carried out and the results appropriately analyzed, can add a lot of value to the product. On the other hand, when used without criteria and data analyzed inappropriately, they can lead to gross errors.

Below we present some basic concepts of accelerated testing, as well as stress variables and ways to apply stress levels. Furthermore, we present some important considerations for carrying out such tests.

1.5.1 Basic Concepts

The theory of accelerated life tests encompasses concepts already seen previously, such as failure, types of censorship and also other specific concepts that are used only in these types of tests. Below we present some basic concepts that are important for understanding this theory.

Accelerated Life Tests

Accelerated tests are those in which the answer of interest is the “time until failure occurs”. The objective in this case is to estimate, for example, the MTTF (MTBF) and the reliability function. By modeling such data, we can extrapolate, with some care, the results obtained in the tests to normal conditions of use.

To illustrate, let’s consider RAM-type computer memories (“random access memory”) manufactured by an industry. One of the performance measures of this product is access time. “Failure”, in this case, could be defined as “access time exceeding a pre-determined value”. Therefore, in an accelerated life test for this product, the answer of interest would be the “time required for the memory access time to become greater than the pre-established value”. To do this, this data is collected under some stressful condition, such as higher temperature.

As another example, let’s consider any frozen product. Suppose that the stress factor for testing is temperature (product units are tested at temperatures higher than the storage temperature). Therefore, a measure of interest is the level of microorganisms in the product. The “failure” in this case would be the “level of microorganisms exceeding a value specified or tolerated by the human organism”. Therefore, in an accelerated life test, the answer would be “time until the level of microorganisms exceeds the specified value”. This makes it possible to determine the product’s expiration date. Let us remember that, in an accelerated life test we stipulate its duration period and at the end we examine the units. Therefore, we run the risk of encountering any of the following situations:

examine all units of the product at the end of the test and consider that none of them “failed” (right censored sample) or;

verify that, for all units, the level of microorganisms exceeded the permitted limit; however, we do not know at what point in time this happened (censored sample on the left) or;

a mixture of the two previous situations.

1.5.2 Stress Variables

A stress variable is one that, when used in a test at levels different from those considered under normal conditions of use (normally at higher levels), shortens the time until failure of the product or material. Let us return to the example of RAM-type computer memories. We know that, for this device, the nominal voltage for use is 5 volts and when used at higher levels the voltage accelerates the degradation of the product. Therefore, tension is a stress variable for these memories. For food products, temperature and humidity are generally stress variables.

Ways to Accelerate Testing

Generally speaking, we speed up a test by subjecting drives to higher levels of stress than those encountered under normal conditions of use. In other words, we chose levels for the stress variables that are much higher than those to which the products are subjected under normal conditions of use (certain tests can be accelerated by using low levels for the stress variables, however, this is not very common). The forms of acceleration can be divided according to two types of stress variables:

Acceleration due to high usage rate

In this case, the stress variable is usage. The product is put into operation, however, with a higher than normal usage rate. This can be done in two ways:

higher speed - for example, running an engine at a higher speed than it would normally run;

reduction of resting time - in this case, the automatic window actuation mechanism is a typical example. The mechanism is left running for a certain number of cycles greater than the expected daily number. Another example is a washing machine. In a home, it is believed that it is in operation for one or two hours a day. In a test, we could run it for 24 hours, uninterruptedly.

Acceleration due to high levels of stress

In this case, the product is subjected to high levels of stress variables with the aim of shortening its lifespan or degrading the product’s performance more quickly. In this type of acceleration, stress variables can be defined as temperature, voltage, vibration, among others.

For some types of materials and products, it is already possible to have an idea of ​​what the most common stress variables are. Some examples are presented in Tables 1.5.1 and 1.5.2.

Materials Performance Measurement Stress Variable
1. metals cracking, corrosion, oxidation temperature, humidity, salt
2. dielectrics and insulators time to failure, stretching temperature, voltage, vibration
3. food and drugs storage time, pH specific chemical reactions temperature, humidity, solar radiation
4. plastics mechanical properties, color fastness temperature, vibration, shock

Table 1.5.1: Examples of Materials, Performance Measures and Stress Variable.

Products Performance Measurement Stress Variable
1. semiconductors and microelectronic components time to failure and operating characteristics temperature, current, voltage, humidity, pressure
2. Capacitors time to failure temperature, voltage, vibration
3. resistors time to failure temperature, voltage, vibration
4. electrical contacts corrosion, time to failure temperature, humidity, current
5. lamps time to failure, efficiency, luminosity voltage, temperature, shock (electrical or mechanical)

Table 1.5.2: Examples of Products, Performance Measures and Stress Variables.

Ways of Applying Stress Load (or Level)

The stress load in an accelerated test can be applied in several ways. We emphasize that these forms only apply to the second type of stress variable discussed in the previous topic, that is, variables other than “use”. Below we present some ways of applying stress load.

Constant: is the most common type. Each unit is subjected to a constant level of stress. Note that, in order for us to model the data obtained, we must use various stress levels. However, once the stress level has been set for a given unit, it will remain at this level until the end of the test. The advantages of this way of applying stress range from the simplicity of performing the test to the use of simple models to analyze the results. Models based on constant stress are defined in the literature and empirically verified for some materials and products. Data analysis for estimating reliability functions is also well defined and available in computational packages. Due to the fact that many products, when in use, are subjected to constant levels of stress, it would be reasonable to focus on this form of applying stress load.

Stair (“step stress”): Each unit is subjected to a level of stress for a period of time. If the unit does not fail, the stress level is raised to a new level and the procedure is repeated. Therefore, in this form of load application, the stress level is increased in small “steps” until failure occurs. The main advantage of “step stress” is to quickly subject each unit to failure. On the other hand, its biggest disadvantage lies in the estimation of reliability measures. Most products under normal conditions of use are subjected to a constant load and not of the “ladder” type. Therefore, the model must adequately take into account the cumulative effect of exposure to constant stress. Another disadvantage of “step stress” is that the failure models that occur at higher levels, in general, differ from those that occur under normal conditions of use.

Progressive: each unit is subjected to an increasing level of stress, but this increase is not done at more progressive levels. The use of progressive stress tests has the same advantages and disadvantages as the “ladder” type. Furthermore, it may be difficult in an accelerated test to control the progressive increase in stress level.

Important Considerations for Conducting an Accelerated Test

The validity and accuracy of information from an accelerated test depend on careful planning and implementation. This is work that must be developed jointly, by Engineers and Statisticians. Below, we list some important elements, which, well defined, will guarantee the validity and accuracy of the information. Remembering that we are dealing with accelerated tests to estimate product reliability measures under design conditions.

Choice of performance measure: for many products there are already technical standards that define which performance measures to be used and how to measure them. Performance measurements for some materials and products are presented in Tables 1.5.1 and 1.5.2 described above. In statistical terminology, the performance measure is called the response variable.

Definition of “failure”: It is important that the manufacturer and consumer agree in advance on the definition of failure to avoid future problems.

Determining Realistic Test Conditions: ideally, an accelerated test should accurately simulate real conditions of use, except for the levels of the stress variable used. However, despite efforts, many tests differ from actual usage conditions. Therefore, Engineers assume (based on experience) that a product that performs well in tests will perform well in use.

Definition of Stress Variables: In this case, we are faced with the fact that, for many products, there are standards/norms for testing and acceleration stresses. Some examples of these patterns/norms of stress variables are presented in Tables 1.5.1 and 1.5.2. However, for other products there may be no established standard. In this case, appropriate stresses must be determined through experimentation. There are still cases where it may be convenient and/or necessary to use more than one stress variable, and it is of fundamental importance to recognize which stress actually reduces the product’s lifespan.

Definition of the Way of Applying the Stress Load: the choice of the way of applying stress load (constant, ladder, etc.) depends on how the product is overloaded under the conditions of use and practical and theoretical limitations. However, as we have already discussed, constant stress is preferable over other types.

Choosing the Trial Plan: an experimental plan is made up of three elements, discussed below. Therefore, choosing a trial plan means:

Determine stress levels: the stress levels that are used must not be so high as to produce new failures under design conditions. Even so, the levels must be high enough to cause active failures to appear in the project. This requires adequate experimentation, prior to testing, so that stress levels can be well defined,

Determine sample size: determine how many units in total will be tested,

Determine allocation ratio: given a sample with n units and the number of stress levels, we must determine how many units will be tested at each level. Traditional engineering sets a total of three to four stress levels and allocates the same number of units to each level. This practice generates less accurate lifetime results at low levels, as failures occur less frequently. At lower levels, a greater number of units must be tested than at higher levels.

1.5.3 Stress-Response Relationship

We begin this topic with some ideas that are of fundamental importance for understanding the concepts introduced below. Even though we are already familiar with experiments, whatever their purpose, we have come across situations in which, even keeping the experiment conditions fixed, for example temperature or voltage, we do not always obtain the same results. This finding can have its origins in the most varied causes, from problems with the measuring device to the fact that we cannot control all the sources of variability involved in an experiment, either due to lack of knowledge about them or the practical impossibility of carrying out such control. Given these conditions of variability, we can say that the time to failure (response) is related to stress (stress variable) according to a model given by

$\hbox{Tempo} = f \hbox{(estresse)} + \hbox{erro}$

The function “f” must have a functional form such that it expresses a decreasing trend. This function is what we call the “stress-response relationship”, and it could take any form, e.g.

  • $\hbox{tempo} = \hbox{(estresse)}^{-2}$

  • $\hbox{tempo} = \hbox{(estresse)}^{-3}$

In fact, we use models that have some physical or chemical meaning as stress-response relationships. The most common are those of Arrhenius and Inverse Power, discussed below. We can note that the stress-response relationship is a model deterministic, that is, for a given value of the stress variable we obtain a single value for the time to failure. However, using only this deterministic relationship we are not able to explain the variability of values ​​found for the response variable at the same stress level. Therefore, it is necessary to add to the deterministic component (stress-response relationship) a probabilistic component, which is capable of explaining the variability in failure times of the units under test at the same stress level. Thus, for each stress level, unit failure times follow a given probability distribution, with the probabilistic component of the model being described by this distribution. However, the models discussed here have a deterministic component and a probabilistic component, defined according to the distribution of time to failure. Below we present two stress-response relationships most used in practice in models for accelerated life tests.

Arrhenius relation

The Arrhenius relationship is used to relate the product failure time and the temperature stress variable. Some application examples include:

  • dielectrics;

  • plastics;

  • filaments of incandescent lamps.

This relationship is based on Arrhenius Law. According to this law, the rate of a simple chemical reaction (1st order) depends on the temperature according to the expression

$$\hbox{Taxa} = A^{\prime}\exp\left[-\dfrac{E}{k \times \hbox{Temp}}\right] \tag{5.3.1}$$

in which

  • E is the activation energy, normally in electron volts;

  • k is Boltzmann’s constant: $8,6171 × 10^{-5}$ by K (Kelvin);

  • Temp is the absolute Kelvin temperature $(273,16 + ºC)$ and

  • A' is a constant that is characteristic of the product failure mechanism and test conditions.

Thus, we can explain the failure due to a chemical reaction or diffusion through a very simple relationship. Assuming that the product failed when a critical amount of the chemical reacted, a simplified view of this situation can be given by:

$$\hbox{Quantidade~Crítica} = \hbox{Taxa} \times \hbox{Tempo até a Falha}$$

or equivalently,

$$\hbox{Tempo até a Falha}=\dfrac{\hbox{Quantidade Crítica}}{\hbox{Taxa}}. \tag{5.3.2}$$

Therefore, we have that the time until failure T is inversely proportional to the rate (5.3.1). The combined use of (5.3.1) and (5.3.2) gives rise to the Arrhenius Relation, given by

$$T = A \exp\left(\dfrac{E}{K \times \hbox{Temp}}\right), \tag{5.3.3}$$

in which $A = (\hbox{Quantidade~Crítica})/A^\prime$.

Applying the logarithm to both sides of (5.3.3) we obtain the linearized form

$$\log(T) = \beta_0 + \dfrac{\beta_1}{T}$$

or even,

$$\log(T) = \beta_0 + \beta_1x, \tag{5.3.4}$$

being that

$\beta_0 = \log(A),~\beta_1 = \left( \dfrac{E}{k} \right)~{e}~x = \dfrac{1}{T}.$

Note that $x = 1/T$ is the inverse of absolute temperature. However, we often work with $x = 1000/T$ to avoid computational problems arising from the use of very small numbers.

The Arrhenius relation shows that the logarithm of the failure time, $\log(T)$, is a linear function of the inverse of the absolute temperature, $x = 1/T$. In applications, it is common to use, instead of failure time $T$, a specified percentile, or the mean of the distribution of the logarithm of failure time. The most common choices are 50th (median time), 63.2th (median time), and 10th percentiles. From the Arrhenius relation in the form (5.3.3) we derive the Arrhenius Acceleration Factor, which is the ratio between the failure time $T_{1}$ at temperature $D_{1}$ and failure time $T_{2}$ at a reference temperature $D_{2}$. This factor is given by

$$A_c=\dfrac{T_1}{T_2}= \exp\left(\dfrac{E}{K}\left[\dfrac{1}{D_1}-\dfrac{1}{D_2}\right]\right)$$

Example 5.3.1

Consider a class H of insulators, E $\thickapprox 0,65 \hbox{eV}$. The acceleration factor $A_{c}$, between $T_{1} = 453,16 K$ (design temperature, equivalent to 180ºC) and $T_{2} = 533,16$ K (260ºC) is given by

$$A_c=\exp\left(\dfrac{0,65}{8,61\times10^{-5}}\left[\dfrac{1}{453,16}-\dfrac{1}{533,16}\right]\right)=12.$$

Therefore, $A_{c} = 12$ This means that items operating at 180ºC last about 12 times longer than those operating at 260ºC.

Note that the calculation of the acceleration factor is deterministic, that is, it does not take into account the variability implicit in experimental data.

Inverse Power Ratio

This relationship is used to model failure time as a function of any type of stress variable. Some example applications include:

  • incandescent lamps

  • metal fatigue

  • insulators, dielectrics, among others.

Suppose the stress variable V is positive (as it is in most situations). The inverse power relationship has the following form

$$T = \dfrac{A}{V^{\beta_1}}, \tag{5.3.5}$$

where T is the time to failure, A and $\beta_1$ are characteristic parameters of the product, geometry, manufacturing, test method, etc.

Still, we can write

$$\log(T) = \beta_0 + \beta_1[-\log(V)] = \beta_0 + \beta_1x, \tag{5.3.6}$$

in which $\beta_0 = log(A)~$ and $~x = -\log(V)$. From expression (5.3.5) we derive the Acceleration Factor between the failure time $T_{1}$ on stress level $V_{1}$ and failure time $T_{2 }$at the reference stress level $V_{2}$, given by

$$A_c = (V_2/V_1)^{\beta_{1}}.$$

From expressions (5.3.4) and (5.3.6) we can derive a general form for the stress-response relationship, given by

$$\log(T)=\beta_0 +\beta_1x,$$

in which

  • if $x=\left(\dfrac{1}{T}\right),$ with T being the absolute temperature, we have the Arrhenius relation and

  • if $x=-\log(V),$ with V being any stress variable, we have the Inverse Power relationship.

Note: In the Appendix we present a summary of the stress-response relationships in log-linear form, showing the equivalence between the parameters.

1.5.4 Applications of Stress-Response Relationships in conjunction with Probabilistic Models

In this topic, we present some important aspects of a plan for carrying out reliability testing. Be they:

  1. an understanding of the functional and reliability requirements of the product;

  2. an understanding of the operational and environmental conditions under which the product will operate;

  3. the expected failure modes and mechanisms;

  4. an acceleration model for each failure mechanism (stress-response relationship) to perform the test and analyze the results;

  5. ability to design and conduct the test;

  6. ability to analyze physical failures;

  7. ability to interpret results and draw conclusions.

Among the aspects mentioned above, we only deal with item 7. We also present a simplified example of applying the Arrhenius relationship to semiconductors, combined with the Exponential Probabilistic Model.

Example 5.4.1

Application of the Arrhenius relationship in conjunction with Exponential Distribution. The manufacturer of a microprocessor carried out dynamic life tests at 125ºC, on a total of 1000 components, having observed a total of 37 failures at the end of the tests, which lasted 1000 hours (963 observations are censored).

The 37 failure times (in hours) observed are: 1, 23, 54, 55, 68, 102, 104, 117, 139, 179, 188, 189, 211, 230, 230, 249, 250, 279, 282, 282, 298, 322, 325, 330, 344, 351, 354, 357, 373, 409, 495, 503, 537, 548, 657, 879, 1300.

It is known that the activation energy of the failure mechanism triggered by the test is 0.4 eV. We are interested in determining the failure rate at an operating temperature of 35ºC. To solve the problem, we consider the following steps:

1. Build the probability role in Software Action in order to choose the most appropriate probabilistic model (Weibull, Exponential and Log-normal).

Distribution Anderson-Darling P-value
Normal(mu = 313.89, sigma = 250) 1.4632 0.0008
Exponential(Rate = 0.00318581) 1.5755 0.0247
Weibull(Shape = 1.27843, Scale = 337.12) 0.6049 0.1112
Log-Normal(log(mu) = 5.3529, log(sigma) = 1.19469) 2.1274 0

Table 1.5.3: Anderson Darling Test

Figura1.5.1

Figure 1.5.1: QQ-plot

2. Estimate the parameters of the exponential distribution.

Since the exponential distribution is suitable for representing the data, we can estimate the MTTF by

$$\widehat{\alpha}=\widehat{\hbox{MTTF}}=\dfrac{\sum_{i=1}^{n} t_i}{r}=\dfrac{11614+(963 \times 1000)}{37}=26341~\hbox{horas}.$$

3. The Arrhenius equation can then be written as

$$\widehat{\lambda_{35}}=\widehat{\lambda_{125}}\exp\left(\dfrac{E}{K}\left(\dfrac{1}{T_{125}}-\dfrac{1}{T_{35}}\right)\right)$$

in which

  • $T_{35}$ = 308ºK;

  • $T_{125}$ = 398ºK;

  • E = 0.4 eV for the considered failure mechanism;

  • $\widehat{\lambda}_{125}= 1/\widehat{\hbox{MTTF}}= 37964 \times 10^{-9}~\hbox{falhas} / \hbox{item-hora}.$

Therefore,

$$\widehat{\lambda}_{35}=37964 \times 10^{-9}\exp\left(\dfrac{0.4}{8.6 \times 10^{-5}}\left[ \dfrac{1}{398}-\dfrac{1}{308}\right]\right)$$

$$=1248\times 10^{-9}~\hbox{falhas}/ \hbox{item-hora}=1248~\hbox{fits}.$$

Some comments

Note that it is only possible to use the Arrhenius acceleration factor if the activation energy for the failure mechanism is known. However, there are tabulated values ​​of activation energy (E) according to the failure mechanism and the stress variable (see tables in the Appendix). On the other hand, when the activation energy is not known, it must be estimated from experimental data. In this case, we must conduct accelerated life tests at different temperature levels in such a way that the activation energy can be estimated by the slope of the straight line passing through the points. Furthermore, it is worth noting that small variations in E can cause huge changes in the extrapolated values. Therefore, it is of great importance to obtain accurate estimates of the parameters involved in the stress-response relationship equations.