13.6 Accelerated Stability - Modified Arrhenius
Modified Arrhenius
It is known that relative humidity, absolute humidity, and water vapor pressure are linearly correlated at constant temperature, meaning that it does not matter which of these humidity measurements are used to model the rate of degradation. However, when modeling the combined effects of temperature and humidity on degradation rate, different humidity descriptors result in different models. Thus, unlike the Arrhenius Chapter, in which only temperature was considered, in this chapter we will deal with a modification of the Arrhenius equation that takes into account the combination of temperature and relative humidity in the degradation rate.
We will present here a modification to the Arrhenius equation so that we have a model in which the degradation rate increases exponentially with relative humidity. This is a combined temperature and humidity model in which relative humidity is used to describe humidity, i.e. it is a model that incorporates an Arrhenius dependence on temperature along with the effects of humidity. Proposed by Genton and Kesselring (1977); Waterman and Adami (2005); Waterman et al. (2007) and Waterman (2009), the modified Arrhenius equation is given by
$$ \begin{equation} K = A\times \exp\left(-\dfrac{E_0}{R \times T}\right)\times \exp(B\times RH), \tag{3.6} \end{equation} $$
and applying the logarithm, we have
$$ \begin{equation} \ln K = \ln A -\dfrac{E_a}{R \times T} + B\times RH. \tag{3.7} \end{equation} $$
The explanation of this model comes from the fact that it is largely empirical in nature and that it is known that relative humidity affects molecular mobility and, therefore, increases the collision frequency and the pre-exponential constant of the Arrhenius Equation.
No interaction term (cross term) is proposed in this model, i.e., the degradation rate temperature is independent of the relative humidity and the degradation rate humidity is independent of the temperature. The use of relative humidity (RH) and not vapor pressure (VP) or absolute humidity (AH) is due to the fact that RH provides the best fit to experimental data. Studies on many different products have provided support for this model.
Equation 3.7 can be viewed in terms of a three-dimensional graph in which the response variable, $\ln k$, is on a plane with an inclination of $-E_a/R$ along the temperature axis and a slope of $B$ along the relative humidity axis, showing how the term $E_a$ is a “temperature sensitivity” parameter and $B$ it is a “moisture sensitivity” parameter.
The coefficients $A$, $-E_a/R$ and $B$ can be calculated using multiple nonlinear regression of Equation 3.6 or multiple linear regression of Equation 3.6. Multiple linear regression uses $\ln k$ as the measured variable (response) and $1/T(K^{-1})$ and %$RH$ as input variables.
Estimation
Linear degradation model
When monitoring the chemical degradation of pharmaceutical products, the measured result is normally given as a percentage by mass of the degradation product in relation to the total mass of the drug substance and its related impurities. This result can be expressed as $\char37\text{Deg}_t$, where $t$ is the time taken to obtain it. To calculate the degradation rate, $k$, you need to know $\char37\text{Deg}$ and storage time $t$. Se $\char37\text{Deg}$ increases linearly with time, we can formulate the following expression to calculate the degradation rate:
$$ \begin{equation} K = \dfrac{\char37\text{Deg}_t}{\text{tempo}(t)} \quad(\text{ordem zero}) \tag{3.8} \end{equation} $$
where the reference “zero order” is used to say that the speed of the reaction remains unchanged as the reactant substance decreases, that is, it is constant (raised to zero). The units commonly used to calculate the rate $k$ are the percentage ($\char37$) per month or day. This way, the results can be compared with the specification limits which are also usually given as a percentage. It is important to note that most zero-order reactions are actually first- or second-order reactions, which, due to reagent consumption, are stopped before the rate of degradation begins to noticeably decrease resulting in an apparently linear degradation.
Nonlinear degradation profiles
When dealing with solid pharmaceutical products, non-linear degradation profiles are much more common to find than linear profiles. Below we mention some of the reasons that lead to this non-linearity:
- Complex chemical degradation mechanisms: the degradation mechanism of some products may involve several reversible, concurrent or consecutive steps.
- Heterogeneous physical states: There may be different physical states and API environments, and each state may exhibit a different susceptibility to degradation. Furthermore, the physical states of samples can change over time resulting in different levels of degradation.
- Degradation limits $\char37\text{Deg}_{\infty}$ unknown and less than 100%: may occur when the reaction rate is proportional to the limiting reactant about to be consumed or when only a small proportion of the API is in a reactive state.
- Nonlinear physical and solid state processes: occurs when there is nucleation, diffusion or volume contraction in the solid state. In this way, the rate limit speed of the degradation process proceeds through nonlinear kinetics.
- Environments where humidity varies: the rate of degradation for most products is significantly affected by humidity, for example, packaged products may experience increases in humidity as the humidity within the packaging will normally slowly increase towards that of the external environment as a result of moisture permeation through the packaging. In this way, the degradation rate is affected.
When any of the types of nonlinear degradation profile mentioned above arises, the need to find a value “$k$” to model the effects of temperature and humidity is generally non-trivial. But it is important to make sure that similar degradation profiles are obtained under different temperature and humidity conditions.
We present, in Table 13.3.1, kinetic models for common nonlinear solid state degradation processes, which are the zero, first and second order degradation kinetic expressions.
| Kinetic Model | Differential Formula $\left(\dfrac{d\alpha}{dt}=\right)$ | Integral Formula $\left(k=\right)$ | Integral Formula $\left(\alpha=\right)$ |
|---|---|---|---|
| Zero Order | $k$ | $\dfrac{\alpha}{t}$ | $kt$ |
| First Order | $k(1-\alpha)$ | $\dfrac{-\ln(1-\alpha)}{t}$ | $1-e^{-kt}$ |
| Second Order | $k{(1-\alpha)}^2$ | $\dfrac{{(1-\alpha)}^{-1}-1}{t}$ |
Table 13.3.1: Kinetic expressions of solid state degradation
The goal of applying a kinetic model approach is to extract a meaningful rate constant, $k$, of the degradation versus time curve, which is then used as the response variable in the stability model accelerated with temperature and humidity. Kinetic models are available for a variety of degradation processes and mechanisms, some of which are listed in Table 13.3.1, where the listed kinetic expressions can be thought of as options for the linear transformation of the degradation curve. The third column of Table 13.3.1 shows how it can be calculated from $\alpha$ (the extent of degradation or degree of conversion) and time ($t$); $\alpha$ in this context it can be calculated using the following equation:
$$\alpha = \dfrac{\char37 \text{Deg}_t}{ \char37 \text{Deg} _{\infty}}$$
Often, the level of degradation of the product at the beginning of the study predicts accelerated predictive stability ($\char37\text{Deg}_{0}$) is nonzero, in which case it may be preferable to define $\alpha$ using the following equation:
$$ \begin{equation*} \alpha = \frac{\char37\text{Deg}_t - \char37\text{Deg}_0}{\char37\text{Deg}_\infty - \char37\text{Deg}_0}, \end{equation*} $$
where the degradation limit $(\char37 \text{Deg}_{\infty})$ it is a parameter that is unlikely to be known a priori; therefore, it is typically left at 100% or is estimated from the degradation profiles (i.e., an additional “model tuning parameter” is used). We will consider that $\char37\text{Deg}_{\infty} = 100\char37$ .
Example
With the intention of exemplifying the accelerated stability test (Modified Arrhenius), let us consider the data set found in Table 13.3.8, which contains information on temperature, in degrees Celsius, humidity, the duration in days of exposure of that medicine to that temperature and humidity in addition to the level of degradation. The aim is to estimate the degradation rate for a temperature of 25ºC and humidity of 60%RH over 365 days.
| Duration (Days) | Temperature (C) | Humidity (%RH) | Degradation Level (%) |
|---|---|---|---|
| 14 | 50 | 75 | 0,42 |
| 14 | 60 | 40 | 0,45 |
| 14 | 70 | 10 | 0,62 |
| 2 | 70 | 75 | 0,66 |
| 2 | 80 | 40 | 0,65 |
Table 13.3.8: data set for accelerated stability test (Modified Arrhenius)
First, we estimate the degradation rate ($K$) in each condition combined by different temperature and humidity, using the linear model:
$$ \begin{equation} K = \dfrac{\char37\text{Deg}_t}{\text{tempo}(t)} \end{equation} $$
in which
- $\char37\hbox{Deg}_t$: percentage of degradation over time $t$, is obtained by subtracting degradation observed over time $t$ of initial degradation ($\char37 \hbox{Deg}_0 = 0,05$);
- $t$: duration of time.
Below, we present the data with the estimated rates.
| Duration (Days) | Condition | Degradation | $\mathbf{\char37\hbox{Deg}_t}$ | $\mathbf{K}$ |
|---|---|---|---|---|
| 14 | 50°C/75%RH | 0,42 | 0,37 | 0,0264 |
| 14 | 60°C/40%RH | 0,45 | 0,4 | 0,0286 |
| 14 | 70°C/10%RH | 0,62 | 0,57 | 0,0407 |
| 2 | 70°C/75%RH | 0,66 | 0,61 | 0,305 |
| 2 | 80°C/40%RH | 0,65 | 0,6 | 0,3 |
Table 13.3.9: Estimation of rates
From the estimated rates, we adjusted a multiple linear regression model according to the Modified Arrhenius equation given by:
$$ \begin{equation} \ln K = \ln A \dfrac{E_a}{R}\times \dfrac{1}{T}+B\times RH \end{equation} $$
in which
- $\ln K$: is the response variable being $K$ the estimated degradation rate;
- $\ln A$: constant factor;
- $E_a/R$: angular coefficient associated with temperature;
- $1/T$: inverse of absolute Kelvin temperature;
- $B$: angular coefficient associated with relative humidity;
- $RH$: relative humidity
The data used to perform the adjustment of the multiple linear model are presented in the following table.
| Condition | Inverse Temperature | Humidity (%RH) | ln K |
|---|---|---|---|
| 50°C/75%RH | 0,0031 | 75 | -3,6333 |
| 60°C/40%RH | 0,003 | 40 | -3,5553 |
| 70°C/10%RH | 0,0029 | 10 | -3,2012 |
| 70°C/75%RH | 0,0029 | 75 | -1,1874 |
| 80°C/40%RH | 0,0028 | 40 | -1,2040 |
Table 13.3.10: Data for the multiple linear regression model
The next step will be to perform an analysis of variance (ANOVA) to test the influence of temperature and humidity on the model.
| G.L. | Sum of Squares | Medium Square | Stat. F. | P-value | |
|---|---|---|---|---|---|
| Inverse Temperature | 1 | 3,8542 | 3,8542 | 1069,3304 | 0,0009 |
| Humidity (%RH) | 1 | 2,4151 | 2,4151 | 670,0593 | 0,0015 |
| Waste | 2 | 0,0072 | 0,0036 |
Table 13.3.11: ANOVA Table
In Table 13.3.11 we see that the p-value is less than 0.05 for temperature and humidity, so we conclude that both variables are influential in the model. Fitting the multiple linear regression model with the values of $\ln(K)$ we obtain the following estimates:
| Estimate | Standard Deviation | Stat. t. | P-value | |
|---|---|---|---|---|
| Intercept | 36,0193 | 0,9603 | 37,5094 | 0,0007 |
| Inverse Temperature | -13581,7589 | 333,4129 | -40,7395 | 0,0006 |
| Humidity (%RH) | 0,0314 | 0,0012 | 25,8855 | 0,0015 |
Table 13.3.12: Coefficients
In this example, we want to estimate the degradation rate for a temperature of 25ºC and humidity of 60%RH for 365 days. Thus, we calculate the inverse of the Kelvin temperature and apply these values to the adjusted model, that is, $$ \frac{1}{T} = \frac{1}{25+257,5} = \frac{1}{282,5} = 0,003354$$ and then $$\widehat{\ln(K)} = 36,019 + (- 13581,759)\ast 0,003354 + 0,0314\ast 60 = -7,64978$$ like this $$\hat{K}=\exp( -7,64978) = -0,000476147.$$
By multiplying this value by 365 days $$-0,000476146\ast 365 = 0,173793.$$
Therefore, the predicted degradation rate at temperature 25º C and humidity 60% RH for 365 days is 0.173793, that is, it is estimated that the medicine loses approximately 17.38% of the content of the analyzed substance per year, if exposed to a temperature of 25º C and humidity 60% RH.
Figure 13.3.2: 3D graph of predicted degradation rate