| Machine Capacity Study Form |
No. |
| Purpose of the Study: |
|
| Type of Machine (equipment): |
|
| Machine Identification No. |
|
| Machine Manufacturer |
|
| Study Date: |
Study No.: $\qquad$ |
| Part Name: |
Part No.: $\qquad$ |
| Feature: |
LIE = $\qquad$ LSE =$\qquad$ |
| Nominal Value (Target): |
Units of Measurement:$\qquad$ |
| Instrument Type: |
Instrument No.:$\qquad$ |
| R&R: |
|
| Calibration Method |
|
| Person who measured the pieces: |
|
| Person who operated the machine: |
|
| Material Identification: |
|
| Material Condition: |
|
| Charging Method: |
|
| Machine Feed Rate: |
Speed:$\qquad$ |
| Cycle Time: |
Oil type: |
| Refrigerant: |
|
| Machine Adjustments made during the study (include explanation): |
|
| 1. |
|
| 2. |
|
| 3. |
|
| 4. |
|
| 5. |
|
| 6. |
|
| 7. |
|
| Signature of the person who filled out this form: |
|
| Date: |
|
Table 3.10.1: Front of the machine capacity study form.
| Data Collection and Formulas for Control Chart for n = 5 and k = 10 |
|
| Feature Measurements |
$\qquad$ Statistics |
| Sample |
Ask |
X1 |
Ask |
X2 |
Ask |
X3 |
Ask |
X4 |
Ask |
X5 |
$\bar{X}$ |
R |
| 1 |
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
|
|
| 2 |
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
|
|
| 3 |
11 |
|
12 |
|
13 |
|
14 |
|
15 |
|
|
|
| 4 |
16 |
|
17 |
|
18 |
|
19 |
|
20 |
|
|
|
| 5 |
21 |
|
22 |
|
23 |
|
24 |
|
25 |
|
|
|
| 6 |
26 |
|
27 |
|
28 |
|
29 |
|
30 |
|
|
|
| 7 |
31 |
|
32 |
|
33 |
|
34 |
|
35 |
|
|
|
| 8 |
36 |
|
37 |
|
38 |
|
39 |
|
40 |
|
|
|
| 9 |
41 |
|
42 |
|
43 |
|
44 |
|
45 |
|
|
|
| 8 |
46 |
|
47 |
|
48 |
|
49 |
|
50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Totals |
|
|
| $\overline{\overline{X}} = \frac{\displaystyle\sum^{10}_{i=1}\overline{X}_i}{10} = \dfrac{}{10} = \qquad \qquad \qquad \qquad$ |
$\overline{R} = \frac{\displaystyle\sum^{10}_{i=1}\overline{X}_i}{10} = \frac{}{10}= \qquad \qquad \qquad \qquad$ |
| Amplitude Graph |
|
| $LSC_{r} = 2,115 \ast \overline{R}$ |
$LIC_{R} = 0$ |
| Averages Chart |
|
| $LSC_{\overline{X}} = \overline{\overline{X}} + 0,577 \ast \overline{R} =$ |
|
Table 3.10.2: Back side of the machine capacity study form.
| Form for Data Collection and Calculations for Ratio Testing |
| Tolerance = $\qquad \qquad \qquad$ Confidence Level = $\qquad \qquad \qquad$ Target Cp = $\qquad \qquad \qquad$ |
| Feature Measurements |
|
|
$S_n$ |
Reason Test |
$VCI_n$ |
$VCS_n$ |
| $(X_1)$ |
$(X_2) \qquad$ |
|
|
|
|
|
| $(X_3)$ |
$(X_4) \qquad$ |
|
|
|
|
|
| $(X_5)$ |
$(X_6) \qquad$ |
|
|
|
|
|
| $(X_7)$ |
$(X_8) \qquad$ |
|
|
|
|
|
| $(X_9)$ |
$(X_{10}) \qquad$ |
|
|
|
|
|
| $(X_{11})$ |
$(X_{12}) \qquad$ |
|
|
|
|
|
| $(X_{13})$ |
$(X_{14}) \qquad$ |
|
|
|
|
|
| $(X_{15})$ |
$(X_{16}) \qquad$ |
|
|
|
|
|
| $(X_{17})$ |
$(X_{18}) \qquad$ |
|
|
|
|
|
| $(X_{19})$ |
$(X_{20}) \qquad$ |
|
|
|
|
|
| $(X_{21})$ |
$(X_{22}) \qquad$ |
|
|
|
|
|
| $(X_{23})$ |
$(X_{24}) \qquad$ |
|
|
|
|
|
| $(X_{25})$ |
$(X_{26}) \qquad$ |
|
|
|
|
|
| $(X_{27})$ |
$(X_{28}) \qquad$ |
|
|
|
|
|
| $(X_{29})$ |
$(X_{30}) \qquad$ |
|
|
|
|
|
| Ratio Test = $( S_n )$ / Tolerance |
|
|
|
|
Decision: |
|
|
|
|
|
|
|
|
Table 3.10.3: Back of the form for Sequential S Test.